Every IFC file audited on ForensicBIM is evaluated against 19 rigorous, independent benchmarks.
Explore the complete directory of earned badges, visual medals, and the exact qualifying criteria required to unlock each one.
๐
19 Total Badges
Across 3 Evaluation Domains
๐๏ธ
buildingSMART
ISO 10303-21 & Official Schemas
๐ฏ
100% Objective
Automated Mathematical Verification
๐ก๏ธ Domain: Trust & Validation
Medal Shape: Shield Crest
Trust & Validation
Foundational data integrity, buildingSMART schema conformance, and structural coordinate sanity. These badges verify that your IFC file is compliant, authentic, and free of structural defects.
Valid STEP file
Trust & Validation
Verifies formal buildingSMART schema compliance, standard STEP formatting, and structural syntax validity.
๐ Conditions to Earn
โ
STEP Syntax ValidConforms strictly to ISO 10303-21 clear text exchange structure format.
โ
IFC Schema ValidValidates against official buildingSMART schema specifications (IFC2X3, IFC4, or IFC4.3).
โ
Header Syntax ValidFile header includes valid FILE_DESCRIPTION, FILE_NAME, and FILE_SCHEMA records.
โ
Prerequisites ValidAll schema prerequisite entities and foundational definitions are properly satisfied.
๐ก Criteria Note: All 4 buildingSMART core topics must pass without invalid syntax or schema errors. Any invalid topic marks the badge as failed.
Real IFC
Trust & Validation
Ensures the model carries real BIM semantics rather than being a bare geometric dummy shell.
๐ Conditions to Earn
โ
Proxy Share โค 10%Generic proxy objects (IfcBuildingElementProxy) comprise no more than 10% of total elements.
โ
Unclassified Proxies โค 2%Proxies lacking classification references represent at most 2% of all elements in the model.
โ
Carries Effective DataAverage effective property facts per element is strictly greater than 0.
โ
โฅ 30% Standard Psets or URI PropertiesAt least 30% of properties are standardized buildingSMART property sets (Pset_*) or link to verified external URIs.
๐ก Criteria Note: Requires authoring tools to export native architectural/engineering entities instead of unclassified meshes.
Clean export
Trust & Validation
Validates that the export contains zero structural errors, negative dimensions, or spatial hierarchy defects.
๐ Conditions to Earn
โ
Semantic IFC ElementsModel must not consist entirely of 100% generic proxies without classification references (non-IFC data).
โ
No Duplicate GlobalIdsExactly 0 duplicate GlobalIds (GUIDs). Every object is globally unique across the dataset.
โ
No Negative QuantitiesZero negative dimensions across all physical measurements (length, area, volume, weight).
โ
No Spatial Structure WarningsAll physical elements are properly contained within the spatial decomposition hierarchy without orphaned elements.
โ
Exactly One SiteDataset contains exactly 1 IfcSite entity representing the project parcel.
๐ก Criteria Note: Eliminates corrupted database entries, proxy-only dummy data, and spatial misalignment when federating multi-disciplinary project files.
Georeferenced
Trust & Validation
Anchors the BIM geometry to an official projected Coordinate Reference System (CRS) for real-world GIS and infrastructure positioning.
๐ Conditions to Earn
โ
Map Conversion with a Projected CRSGeoreferencing level โฅ 1 with IfcMapConversion and IfcProjectedCRS defined.
โ
Standardized Schema EntityFull native georeferencing is supported in IFC4 and IFC4.3 (IFC2X3 lacks native CRS entities).
๐ก Criteria Note: Essential for civil engineering, infrastructure interfaces, site logistics, and automated GIS map integration.
bSDD
Trust & Validation
Verifies that building components, classifications, properties, or materials are formally linked to the buildingSMART Data Dictionary (bSDD) via standard identifiers.
๐ Conditions to Earn
โ
URI from buildingSMART Data DictionaryContains at least one URI starting with https://identifier.buildingsmart.org in properties, classification references, or materials.
โ
Non-IFC Domain ClassificationStandard IFC classes and properties (https://identifier.buildingsmart.org/uri/buildingsmart/ifc/) are ignored; custom or national dictionary domains must be referenced.
๐ก Criteria Note: Connects BIM objects directly to web-accessible open international data dictionaries (such as Molio, CCI, Uniclass, AASHTO) via bSDD URIs.
Valid alignment
Trust & Validation
Verifies that horizontal, vertical, and 3D linear alignments maintain continuous geometry and 1:1 business-logic-to-geometry correspondence without layout errors or notes.
๐ Conditions to Earn
โ
Alignments DefinedDataset contains at least one IfcAlignment entity representing a roadway, railway, transit, or tunnel axis.
โ
1:1 Semantic-to-Geometric CorrespondenceEvery business segment (IfcAlignmentSegment) corresponds 1:1 to an underlying geometric curve segment (IfcCurveSegment) with matching segment types.
โ
Zero Layout Warnings and Continuity NotesLayout relationships (ALS016/ALS017) are geometrically continuous across joints with 0 notes and 0 warnings.
๐ก Criteria Note: Ensures linear infrastructure alignments can be used directly for stationing, earthwork modeling, and machine control without manual repairs.
โญ Domain: Data Completeness
Medal Shape: Serrated Medal (Silver & Gold)
Data Completeness
Information depth and element property coverage across the model. Awarded in two distinct tiers: Silver (โฅ 90%) and Gold (โฅ 99.5%). Requires at least 50 elements to ensure statistical significance.
Classified
Data Completeness
Percentage of building elements categorized under a recognized classification system (e.g. UniFormat, OmniClass, Uniclass).
๐ Conditions to Earn
โ
Model Size ThresholdModel must contain at least 50 elements.
โ
Silver Tier: โฅ 90.0%Classification coverage across elements meets or exceeds 90%.
โ
Gold Tier: โฅ 99.5%Classification coverage across elements reaches at least 99.5%.
๐ก Criteria Note: Models with fewer than 50 elements receive an unknown state ("model too small") to avoid awarding 100% medals on trivial sample snippets.
Classified + URI
Data Completeness
Rewards models whose classifications link directly to resolvable external web URIs or Linked Data ontologies.
๐ Conditions to Earn
โ
Model Size ThresholdModel must contain at least 50 elements.
โ
Silver Tier: โฅ 90.0%Both classification coverage and URI reference coverage reach at least 90%.
โ
Gold Tier: โฅ 99.5%Both classification coverage and URI reference coverage reach at least 99.5%.
๐ก Criteria Note: Connects BIM objects directly to web-accessible knowledge bases, standard specification documents, and digital twins.
Materials
Data Completeness
Evaluates whether building components have explicitly assigned material constituents via IfcRelAssociatesMaterial.
๐ Conditions to Earn
โ
Model Size ThresholdModel must contain at least 50 elements.
โ
Silver Tier: โฅ 90.0%Material definition coverage across physical components meets or exceeds 90%.
โ
Gold Tier: โฅ 99.5%Material definition coverage across physical components reaches at least 99.5%.
๐ก Criteria Note: Crucial for embodied carbon assessments, life cycle analyses (LCA), thermal calculations, and procurement bills.
Materials + URI
Data Completeness
Rewards material associations linked to external digital product registers, EPD databases, or circular supply chain URIs.
๐ Conditions to Earn
โ
Model Size ThresholdModel must contain at least 50 elements.
โ
Silver Tier: โฅ 90.0%Both material coverage and material URI coverage reach at least 90%.
โ
Gold Tier: โฅ 99.5%Both material coverage and material URI coverage reach at least 99.5%.
Strict modeling quality ensuring that not a single generic proxy object (IfcBuildingElementProxy) exists in the model.
๐ Conditions to Earn
โ
Model Size ThresholdModel must contain at least 50 elements.
โ
Zero Proxy ObjectsExactly 0 proxy objects (every element is instantiated as its true domain class).
๐ก Criteria Note: Awarded exclusively as a Gold badge. Confirms that no CAD conversion shortcuts or fallback proxies were used.
โก Domain: Fit for Use
Medal Shape: Hexagonal Crest
Fit for Use
Rigorous multi-point readiness checks for specific downstream applications, including automated quantity take-off (QTO), clash-free coordination, generative AI ingestion, facility management, and circularity passports.
Take-off ready
Fit for Use
Certified readiness for automated 5D quantity take-off, cost estimating, and bill of materials generation.
๐ Conditions to Earn
โ
Quantities Coverage โฅ 90%At least 90% of model elements possess defined element quantities.
โ
Materials Coverage โฅ 80%At least 80% of model elements carry assigned materials.
โ
No Negative QuantitiesZero negative measurements across all physical dimensions.
โ
Length Unit DefinedBase project length unit is explicitly declared in project unit assignment.
๐ก Criteria Note: Guarantees quantity surveyors and cost engineers can extract reliable bill of quantities immediately.
Coordination ready
Fit for Use
Suitability for multi-disciplinary clash detection, spatial containment verification, and federated coordination.
๐ Conditions to Earn
โ
buildingSMART Core Checks Not InvalidNo invalid status across buildingSMART syntax, schema, header, or prerequisites.
โ
Recognized MVD DeclaredFile header declares a recognized standard Model View Definition.
โ
Exactly One SiteSingle project site ensures aligned spatial coordinate offsets.
โ
Spatial Containment โฅ 95%At least 95% of components are properly contained within storeys or building facilities.
โ
Proxy Share โค 10%Proxies do not exceed 10% of total elements.
โ
Geometry on โฅ 98% of ElementsAt least 98% of objects carry renderable 3D geometric shapes.
๐ก Criteria Note: Ensures the model can be federated into Navisworks, Solibri, BIMcollab, or Revizto without missing geometry or coordinate drift.
AI ready
Fit for Use
High semantic density and standardized metadata structure required for LLMs, autonomous AI agents, and knowledge graphs.
๐ Conditions to Earn
โ
Classification Coverage โฅ 80%At least 80% of elements carry structured classification codes.
โ
Informative Values โฅ 80%At least 80% of property values contain substantive, meaningful facts.
โ
โฅ 5 Effective Facts Per ElementAverage fact density meets or exceeds 5 distinct property facts per component.
โ
Typed Elements โฅ 80%At least 80% of element occurrences are linked to IFC Types.
โ
โฅ 30% Standard or URI-defined PropertiesAt least 30% of properties follow standard Psets or reference external URIs.
โ
One Site & No Duplicate GlobalIdsClean structure with 1 site and 0 duplicate GUIDs.
โ
Forensic Data Score โฅ 60Forensic Data Score reaches at least 60 out of 100.
๐ก Criteria Note: Prepares BIM models for automated AI query agents, code compliance LLMs, and semantic reasoning engines.
Operations / FM
Fit for UseDraft Specification
Prepares the asset data for operational handover into Computer-Aided Facility Management (CAFM) and CMMS databases.
๐ Conditions to Earn
โ
Spaces PresentModel contains defined rooms/spaces (IfcSpace count > 0).
โ
Classification Coverage โฅ 80%At least 80% of equipment and elements are categorized with classification codes.
โ
Typed Elements โฅ 80%At least 80% of elements link to equipment types.
โ
โฅ 5 Effective Facts Per ElementDense asset metadata with at least 5 facts per element.
โ
No Duplicate GlobalIdsUnique asset identification across the facility.
๐ก Criteria Note: Draft rule: Evaluated under active research criteria while standardized buildingSMART FM dictionaries evolve.
Energy analysis
Fit for UseDraft Specification
Validates space definitions, second-level space boundaries, and material properties for thermal Building Energy Modeling (BEM).
๐ Conditions to Earn
โ
Spaces PresentModel contains defined thermal spaces (IfcSpace count > 0).
โ
Space Boundaries PresentThermal relationships defined via IfcRelSpaceBoundary (> 0).
โ
Materials Coverage โฅ 80%At least 80% of envelope and internal elements carry assigned materials.
๐ก Criteria Note: Draft rule: Requires second-level space boundaries and material assignments for thermal simulation engines.
Product passport
Fit for UseDraft Specification
Designed for circular construction, disassembly tracking, embodied carbon auditing, and Digital Product Passports.
๐ Conditions to Earn
โ
Materials Coverage โฅ 90%High-fidelity material specification on at least 90% of elements.
โ
Classification Coverage โฅ 80%Uniform classification of building components.
โ
Typed Elements โฅ 80%Component types declared for circular reuse.
โ
โฅ 5 Effective Facts Per ElementDeep product metadata including manufacturer, origin, and material properties.
๐ก Criteria Note: Draft rule: Aligned with upcoming EU Digital Product Passport (DPP) guidelines for construction products.
Audit Your BIM Models
See which badges your IFC files can earn today
Upload an IFC file to receive an instant comprehensive audit, forensic quality score, buildingSMART schema verification, and see your earned badges in your personal trophy case.